LOVIBOND® Standard Solutions, Calibration Solutions, and Buffer Solutions



Water
- Tintometer India dedicatedly provides high-quality Standard Solutions, Calibration Solutions, and Buffer Solutions for routine and challenging water analysis.
- Lovibond® Standard solutions are solutions with a defined concentration and are provided to check the operation methods and the condition of the instrument
- Lovibond® Standard solutions can be used in many different ways, with one commonality-they can be used to establish the accuracy and precision of a test method
- Lovibond® Standard solutions are available for many different analytes (and in many concentrations) including nitrate, fluoride, chloride, iron, manganese, nitrate, silica, etc.
- Lovibond® Calibration Solutions are used to calibrate the instruments used for colorimetric, electrochemical, and turbidimetric measurements. Calibrating Water Treatment Instruments Regularly Ensures the Accurate Test Results.


- Lovibond® Calibration Solutions are made under strictly controlled conditions using reagent grade salts. NaCl Solution is routinely used to calibrate instruments measuring different sources of water, sea water or fresh water.
- TDS Solution is used in calibrating many test instruments. It is the best choice when measuring boiler and cooling water samples, city water supply, lakes, wells, etc. Frequency of recalibration depends upon use, but once every month should be sufficient for an instrument used daily.
- Lovibond® Buffer solutions are used as a means of keeping pH at a nearly constant value in a wide variety of chemical applications.
- Lovibond's color-coded pH buffer solutions of range 4.01, 7.00, 9.01, 9.2, 10.01 are accurate and are suitable for calibrating pH electrodes with all types of pH meters, whether using automatic buffer recognition or manually adjustable pH values
- These buffer solutions are extensively used in dying fabrics, in personal hygiene and cosmetics, in printing industry, in leather industry etc.
- Lovibond® Standard Solutions, Calibration Solutions, and Buffer Solutions are available in multiple ranges and different pack sizes, based on the requirement you can order these solutions.
Lovibond® Buffer solutions are used as a means of keeping pH at a nearly constant value in a wide variety of chemical applications. Lovibond's color-coded pH buffer solutions of range 4.01, 7.00, 9.01, 9.2, 10.01 are accurate and are suitable for calibrating pH electrodes with all types of pH meters, whether using automatic buffer recognition or manually adjustable pH values. These buffer solutions are extensively used in dying fabrics, in personal hygiene and cosmetics, in printing industry, in leather industry etc.
Lovibond® Standard Solutions, Calibration Solutions, and Buffer Solutions are available in multiple ranges and different pack sizes, based on the requirement you can order these solutions.
Analysis | Range | Gradations | Pack Size | Method Type | Order Code | Download |
Fluoride | 1000 ppm | 500 ml | Standards | IN2056030-111 | - | |
Fluoride | 1 ppm | 500 ml | Standards | IN2056030-010 | - | |
Fluoride | 0.5 ppm | 100 ml | Standards | IN205630-005 | - | |
Fluoride | 1 ppm | 100 ml | Standards | IN205630-010 | - | |
Fluoride | 5 ppm | 100 ml | Standards | IN205630-050 | - | |
Fluoride | 10 ppm | 100 ml | Standards | IN205630-100 | - | |
Fluoride | 1000 ppm | 100 ml | Standards | IN205630-111 | - | |
Fluoride | 0.5 ppm | 500 ml | Standards | IN205631-005 | - | |
Fluoride | 1 ppm | 500 ml | Standards | IN205631-010 | - | |
Fluoride | 5 ppm | 500 ml | Standards | IN205631-050 | - | |
Fluoride | 10 ppm | 500 ml | Standards | IN205631-100 | - | |
Nitrate | 1000 ppm | 500 ml | Standards | IN2420806 | - | |
Silica | 1000ppm as SiO2 | 500 ml | Standards | IN2100200 | - | |
Manganese | 1000 ppm | 500 ml | Standards | IN2100300 | - | |
Iron | 1000 ppm | 500 ml | Standards | IN2100400 | - | |
Iron | 1000 ppm | 100ml | Standards | IN2100401 | - | |
Chloride | 1000 ppm | 500 ml | Standards | IN2100501 | - | |
Chloride | 500 ppm | 500 ml | Standards | IN2100500 | - | |
Chloride | 1000 ppm | 100ml | Standards | IN2100502 | - | |
COD | 1000 ppm | 30 ml | Standard Solution | IN2420803 | - | |
COD | 500 ppm | 30 ml | Standard Solution | IN2420804 | - | |
COD | 5000 ppm | 10 ml | Standard Solution | IN2420805 | - | |
TDS | 0.01 M KCl | 500 ml | Standard | IN2100600 | - | |
TDS | 0.01 M KCl | 1000 ml (500X2) | Standard | IN2100601 | - | |
TDS | 0.1 M KCl | 500 ml | Standard | IN2100610 | - | |
TDS | 0.1 M KCl | 1000 ml (500X2) | Standard | IN2100611 | - | |
TDS | 3 M KCL | 500 ml | Standard (Electrode Filling solution) | IN2100620 | - | |
Conductivity | 84us/cm | 500 ml | Standard Solution | IN722230 | - | |
Conductivity | 100us/cm | 500 ml | Standard Solution | IN722231 | - | |
Conductivity | 111.88ms/cm | 500 ml | Standard Solution | IN722232 | - | |
Conductivity | 500us/cm | 500 ml | Standard Solution | IN722240 | - | |
Conductivity | 1413us/cm | 500 ml | Standard Solution | IN722250 | - | |
Conductivity | 2764us/cm | 500 ml | Standard Solution | IN722251 | - | |
Conductivity | 12.88ms/cm | 500 ml | Standard Solution | IN722260 | - | |
NaCl | 5.00 ppt | 100 ml | Calibration Solution | IN467621 | - | |
NaCl | 5.00 ppt | 500 ml | Calibration Solution | IN467621-50 | - | |
NaCl | 25.00ppt | 500 ml | Calibration Solution | IN467625-50 | - | |
NaCl | 45.00 ppt | 500 ml | Calibration Solution | IN467629-50 | - | |
TDS | 15 ppm | 500 ml | Calibration Solution | IN733310-50 | - | |
TDS | 50 ppm | 500 ml | Calibration Solution | IN733320-50 | - | |
TDS | 150 ppm | 500 ml | Calibration Solution | IN733330-50 | - | |
TDS | 300 ppm | 500 ml | Calibration Solution | IN733340-50 | - | |
TDS | 1000 ppm | 500 ml | Calibration Solution | IN733350-50 | - | |
TDS | 3000 ppm | 500 ml | Calibration Solution | IN733360-50 | - | |
pH | 4.01 ± 0.02 (25℃) | 100 ml | Buffer Solution | IN721247 | - | |
pH | 4.01 ± 0.02 (25℃) | 500 ml | Buffer Solution | IN721251 | - | |
pH | 4.01 ± 0.02 (25℃) | 1000 ml | Buffer Solution | IN721252 | - | |
pH | 7.00 ± 0.02 (25℃) | 100 ml | Buffer Solution | IN721248 | - | |
pH | 7.00 ± 0.02 (25℃) | 500 ml | Buffer Solution | IN721253 | - | |
pH | 7.00 ± 0.02 (25℃) | 1000 ml | Buffer Solution | IN721254 | - | |
pH | 10.01 ± 0.03 (25℃) | 100 ml | Buffer Solution | IN721249 | - | |
pH | 10.01 ± 0.03 (25℃) | 500 ml | Buffer Solution | IN721255 | - | |
pH | 10.01 ± 0.03 (25℃) | 1000 ml | Buffer Solution | IN721256 | - | |
pH | 9.01 ± 0.02(25℃) | 100 ml | Buffer Solution | IN721257 | - | |
pH | 9.01 ± 0.02(25℃) | 500 ml | Buffer Solution | IN721258 | - | |
pH | 9.01 ± 0.02(25℃) | 1000 ml | Buffer Solution | IN721259 | - | |
pH | 9.2 ± 0.01 (25℃) | 100 ml | Buffer Solution | IN721260 | - | |
pH | 9.2 ± 0.01 (25℃) | 500 ml | Buffer Solution | IN721261 | - | |
pH | 9.2 ± 0.01 (25℃) | 1000 ml | Buffer Solution | IN721262 | - | |
pH | 4.00/7.00/10.00 (25 ℃) | 100 ml X 3 | Buffer Set | IN721250 | - |